Performance and Consumption Task Error: Couldn't get heat pump capacity: ODT out of range This error will usually occur when you have set up a custom heat pump with some missing values. The performance task uses an ODL (outdoor low temp) which is lower than the standard project ODT in Heatpunk. This can mean it works fine in the heat pump task but then there is an issue in performance.  To solve this,  go to the heat pump in My Components . You will need to ensure that the table goes down to -7 degrees to make sure it works in every location. You should be able to find the values you need in the datasheet. Where can I find the solar and battery details in Easy PV? If you're modelling solar and batteries in the Consumption task and also modelling the project in Easy PV, you can find all the required information in your Easy PV project:  Solar Navigate to the Performance task > Performance results : Then for each roof or input: Pitch Orientation Array size Shading: subtract this value from 1 and multiply by 10, then select closest value  Battery Navigate to the Inverter task > scroll down to where the battery is selected on the inverter. You will then see:  Capacity  Max charge rate