Skip to main content

Hot Water Storage - updated

Heatpunk helps you specify a hot water storage solution that's compatible with selected heat pump and sized based on property details. Once selected, you can view specs, domestic hot water (DHW) calculations and Legionella calculations.Ā 

You can fine tune these calculations for the specific requirements of the installation and share these details with customer in the technical report and customer proposal.


Adding hot water storage

CylinderPlacement.gif

Hot water storage is selected in the Plan task.

While on a design option, drag and drop hot water storage from the left-hand sidebar to place the hot water storage in the plan. After placing it, you can select a hot water storage option from theĀ recommendations or scroll through the sections on the left sorted by brand and type (pre-plumbed, standard, pre-plumbed slimline, slimline and horizontal).Ā 

How are the recommended options chosen?

Recommendations are based on compatibility with the heat pump and are sized according to the number of bedrooms and occupants. Adjust the number of bedrooms/occupants and click Recommend to get updated recommendations.Ā 

image.png

This is calculated using the MCS method for DHW demand:Ā 

Recommended volume = 45 * N

where N is the greater of:

  • The number of rooms + 1Ā 
  • The number of known occupantsĀ 

When you have an option selected, on the right you will see spec information, and Midsummer stock and pricing information. If your account is connected to Midsummer, you will also see your specific pricing.Ā 

Editing hot water storage

You will also have the following options to the top right of the Hot water tab on the right-hand sidebar:Ā 

image.png

Edit.jpg

Pencil icon: Edit hot water selection for this design option

image.png

Show/hide all details: Show/hide DHW energy and Legionella purge demand, weight, standing heat loss, coil size and immersion heater size. Read more about these details below.

image.png

Delete cylinder: Remove hot water storage from this design option

Hot water storage details and DHW calculations

You can view details for the chosen hot water storage in the Hot water tab.Ā 

  • Model
  • Nominal capacity (ā„“)
  • Cylinder re-heat time (min)
  • Vdraw/Mix down volume (ā„“)

On the cylinder, click ⋯ three dots > Show all details to view the following:

  • DHW energy demand (kWh/year)
  • Legionella Purge Demand (kWh/year)Ā 
  • Weight (empty | full) (kg)
  • Standing heat loss (kWh / Hrs)Ā 
  • Coil size (m2)
  • Immersion heater power (kW)

These details are then given in the Hot Water Calculations page of theĀ Technical report and Customer proposalĀ for you to share with the customer.Ā 

How is DHW energy demand calculated?

DHW energy demand is calculated using the storage temperature, supply temperature, number of occupants and the water needed per person.Ā 

First the volume of water needed per year is calculated with the following calculation:

Volume per year = number of occupants * the water needed per person * 365

Noting that for water, volume (L) = mass (kg). Then using the specific heat capacity of water (kJ/kg°C), this is converted to kWh/year:

DHW energy demand = 4.2 * (1/3600) * mass per year * (storage temperature - supply temperature)Ā Ā 

Adjusting DHW and Legionella calculations

These calculations can be fine tuned by editing the Hot water preferences on the Hot water tab:

image.png

This will give you the following options to edit under Hot water storage settings:Ā 

  • DHW Storage Temperature (°C)
  • Difference between flow temperature while providing hot water and storage temperature (°C)
  • Flow Temperature while providing hot water (°C) (This is calculated based on the two previous inputs)
  • Draw Water Temperature (°C)
  • Supply Water Temperature (°C)
  • Pipework Efficiency (%)
  • Water used per person per day (ā„“)Ā 

UnderĀ Legionella settings, you then have these options:

  • Legionella purge required (Yes/No)
  • Legionella purge frequency (Weekly/Daily)
  • Legionella heat source (Immersion/Heat pump)
  • Legionella purge temperature (°C)Ā 

Changes to these settings will only affect the selected design option.


Take a look at our Plan taskĀ guidesĀ andĀ FAQsĀ for more info. If you have further questions, please get in touch onĀ help@heatpunk.co.ukĀ orĀ help@heatpunk.ie.Ā